Airbrake - GRAUPNER mz-24 Pro Programming Manual

12 channel hott 2.4 ghz transmitter
Hide thumbs Also See for mz-24 Pro:
Table of Contents

Advertisement

Airbrake

Airplane Braking System Adjustment
This submenu option is not available for certain model
types and configurations.
Use this menu to configure the deflection direction of
the flaps and elevator for braking.
To adjust these settings, from the main display press
the FUNCTION menu gear icon (blue "F") to bring up
the FUNCTION submenu screen:
000%
000:00.0
000
000
mz
000:00.0
0:01:23
Press
M - 2
000
000
PHASE 1
Extra 360
BATT TIME
00: 01: 23
000
From the FUNCTION submenu, press the Airbrake
icon:
BACK
BASE
FUNCTION
Phase
D/R,EXPO
THR.CRV
Idle LOW
Press
Snap roll
Aile diff
Wing MIX
Flap MIX
Airbrake
TTrainer
Logical sw
Sequence
The display shows different views depending on the
selected number of ailerons and flaps. This exam-
ple shows the display for setting a minimum, such as
2AILE:
BACK
PHASE 1
Airbrake
ACT
INH
CTL
ON
AILE1
AILE2
RATE
000%
000%
200 Function menu | Airplane models - brakes
This example shows the display for setting a maxi-
mun, such as 4AILE4FLAP:
000%
4.2V
Phase-Dependent Settings
This submenu allows for different phase-specific val-
ues to be programmed. Phase names are displayed
in green in the upper left side of the screen next to
the BACK button. Standard default naming for the
000
phases are usually displayed as NORMAL/PHASE
1. (Additional phases will be named numerically, e.g.
Phase 2, Phase 3, etc.) To define multiple phases,
SYSTEM
refer to the FUNCTION submenu Phase section (page
120). Each new phase will need to be assigned to a
different switch. To change the phases, activate the
Prog.MIX
corresponding switch(es).
Programming
Flap set
Using either the ACT or CTL options, enter the flap
V-Tail
and elevator deflection direction amount for braking.
In order for these settings to be effective and retriev-
able (e.g. with a switch), program the option fields as
described below:
SERVO
NEXT
INC
RES
DEC
BACK
SERVO
PHASE 1
Airbrake
ACT
INH
CTL
ON
NEXT
FLAP1
FLAP2
INC
FLAP3 FLAP4
RATE
000%
000%
000%
000%
RES
DEC
• ACT Line
To activate
 ON 
or inhibit
 INH 
press to change the value fields on the appropri-
ate screen.
If this phase is assigned to a switch, this individu-
ally turns on and off the effect of the selected con-
trol element on the flap position for specific phases
when the value field is  ON .
• CTL Line
Use this field to assign a control or control switch
to a specific phase mixer. Refer to the Control
and Switch Assignment section (page 26) for in-
formation on assigning switches. In the example
below, the phase titled LANDING is assigned to
S6:
BACK
LANDING
Airbrake
ACT
ON
CTL
SW 6
AILE1
AILE2
RATE
000%
000%
RATE Line
A symmetrical or an asymmetrical effect can be de-
fined for each flap pair. In order to be able to define
upward and downward deflections, the setting range
is ±150%.
Switch to the desired phase and press the value field
to be set. In the example below, the phase titled
LANDING needs the AILE1 RATE changed to +023%:
(Active)
a specific phase,
(Control/Switch)
SERVO
NEXT
INC
RES
DEC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents