GRAUPNER mz-24 Pro Programming Manual page 110

12 channel hott 2.4 ghz transmitter
Hide thumbs Also See for mz-24 Pro:
Table of Contents

Advertisement

When the voltage falls below the set alarm threshold,
a warning tone sounds, and VOLT.E appears in white
at the top right in all RX displays:
BACK
Telemetry
RECV
RX SERVO TEST
VOLT.E
>ALL-MAX
:
2000µsec
GAM
ALL-MIN
:
1200µsec
TEST
:
STOP
EAM
ALARM VOLT
: 3.8V
VARIO
ALARM TEMP+ : 55°C
ALARM TEMP– : –10°C
GPS
CH OUT TYPE : ONCE
ESC
In the RX DATAVIEW display, the parameter R-VOLT is
displayed in white:
BACK
Telemetry
RX DATAVIEW
VOLT.E
RECV
S–QUA100% S–dBM–030dBm
GAM
S–STR100% R–TEM.+28°C
L PACK TIME 00010msec
EAM
R-VOLT
:
03.7V
VARIO
L.R-VOLT : 04.5V
SENSOR1 : 00.0V 00°C
GPS
SENSOR2 : 00.0V 00°C
ESC
ALARM TEMP +/-
(Receiver Temperature
These two options monitor the receiver temperature:
program the bottom threshold ALARM TEMP- (-20
to +10°C) and the upper threshold ALARM TEMP+
(+50 to +80°C). If the upper or lower thresholds are
exceeded, a continuous warning tone sounds, and
TEMP.E appears in white at the top right in all receiver
displays. On the display page RX DATAVIEW, the pa-
rameter R-TEM is also displayed in red or white.
Make sure that the temperature of the receiver re-
mains within the permissible range under all operating
conditions (ideally between -10 and +55°C).
110 Base menu - Telemetry | SETTINGS/DISPLAYS
CH OUTPUT TYPE
In this line, select the type of servo control or signal
type of the aggregate signal output:
• ONCE
ESC
DEC
RX SERVO TEST
INC
ALL-MAX
ENT
ALL-MIN
TEST
SET
ALARM VOLT : 3.8V
ALARM TEMP+ : 55°C
ALARM TEMP– : –10°C
>CH OUT TYPE :
The servo connections of the receiver are actuat-
ed sequentially; recommended for analog servos.
ESC
With this setting, the servos are automatically op-
DEC
erated at a cycle of 20 ms (30 ms for a 12 chan-
INC
nel GR-24 receiver (No. 33512) regardless of what
is set or displayed in the RX SERVO display in the
ENT
SET
line PERIOD.
• SAME
Monitoring)
RX SERVO TEST
ALL-MAX
ALL-MIN
TEST
ALARM VOLT : 3.8V
ALARM TEMP+ : 55°C
ALARM TEMP– : –10°C
>CH OUT TYPE :
The servo connections of the receiver are actuat-
ed simultaneously in blocks: servos connected to
connections 1 to 4 as well as 5 to 8 can be simul-
taneously supplied with their control signals with a
GR-16 receiver (No. 33508), and the servos con-
nected to connections 1 to 4, 5 to 8 as well as 9 to
12 can be simultaneously supplied with their con-
trol signals with a GR-24 receiver (No. 33512).
(Connection Type)
BACK
Telemetry
RECV
ESC
V6.35 <
: 2000µsec
GAM
DEC
: 1200µsec
EAM
INC
: STOP
VARIO
ENT
GPS
SET
ONCE
ESC
BACK
Telemetry
V6.35 <
RECV
ESC
:
2000µsec
GAM
DEC
:
1200µsec
:
STOP
EAM
INC
VARIO
ENT
GPS
SET
SAME
ESC
This is recommended for digital servos when sev-
eral servos are used for a single function (i.e. an ai-
leron) so that the servos are fully synchronized.
When exclusively digital servos are used, it is rec-
ommendable to set 10 ms in the PERIOD line of
the RX SERVO display to increase digital servo re-
action time. When analogue servos or mixed oper-
ation is used, select 20 ms.
Attention
When this setting is used, use increased re-
ceiver power supply. The four servos are al-
ways triggered simultaneously in the SAME
setting, causing greater drain on the power supply.
• SUMO
(Aggregate Signal OUT)
A HoTT receiver configured as SUMO always gen-
erates an aggregate signal from the control signals
of all its controls channels, and forwards this to
servo connection 8 of the GR-16 (No. 33508) and
GR-24 receiver (No. 33512).
With receivers that have a two-digit number to the
right of SUMO line in their display, the selection
determines the highest control channels within the
SUMO signal.
Press the
 INC 
or
 DEC 
button to move the brack-
et to the CH OUT TYPE line, and press the
button at the bottom right of the display. The field
highlights white. Use the
 INC 
select the SUMO setting:
BACK
Telemetry
RX SERVO TEST
V6.35 <
ALL-MAX
:
2000µsec
ALL-MIN
:
1200µsec
TEST
:
STOP
ALARM VOLT
: 3.8V
VARIO
ALARM TEMP+ : 55°C
ALARM TEMP– : –10°C
>CH OUT TYPE :
SUMO
08
 SET 
or
 DEC 
button to
RECV
ESC
GAM
DEC
EAM
INC
ENT
GPS
SET
ESC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents