5.3.4 Connection example to a host controller
+COM input
+COM input
+COM input
24VDC
E-STOP input
START input
S-STOP input
M0 input
M4 input
IN1 input
IN8 input
-COM input
-COM input
The current flow for each output signal is 25mA or less.
CN1
7
16
32
2
3
4
33
37
8
15
25
50
5 5 5 5 5
Series
+5~24VDC
25mA max.
27
ALM output
29
MOVE output
31
READY output
49
END output
17
OUT1 output
22
OUT6 output
Connection
5-7