Event
Logical Drive
Notification, cont.
Logical Drive Migration
Stopped
Logical Drive Rebuild
Start
Logical Drive Rebuild
Completed
Logical Drive Rebuild
Stopped
Logical Drive
Synchronization Start
Logical Drive
Synchronization
Completed
Logical Drive
Synchronization Stopped
Logical Drive
Synchronization
Comparison Error
Logical Drive
Synchronization Internal
Error
Logical Drive Full
Initialization Start
Logical Drive Full
Initialization Completed
Logical Drive Full
Initialization Stopped
Logical Drive Quick
Initialization Start
Logical Drive Quick
Initialization Completed
Logical Drive Quick
Initialization Stopped
User aborted expansion or RAID level change.
Normal.
Rebuild begun. This can happen automatically
depending on Controller settings. Normal.
Rebuild finished. Normal.
User aborted Rebuild. Normal.
Synchronization begun. This can happen
automatically depending on Controller settings.
Normal.
Synchronization finished. Normal.
User aborted Synchronization. Normal.
Data discrepancy found and corrected. If this
message appears frequently, contact Technical
Support.
Data discrepancy found but not corrected. Contact
Technical Support.
Full Initialization started. Normal.
Full Initialization finished. Normal.
User aborted logical drive Full Initialization. Normal.
Quick Initialization started. Normal.
Quick Initialization finished. Normal.
User aborted Quick Initialization. Normal.
213
Chapter 8: Troubleshooting
Action
Need help?