Logical Drive Operations Under The Maintenance Menu - Promise Technology VTRAK 15200 User Manual

Table of Contents

Advertisement

VTrak 15200 User Manual
2.
Press Y and Enter to toggle PDM between Enabled and Disabled.
3.
Press 1 and Enter to specify remap percentage.
Current remap percentage threshold: 0%
Change the threshold(y/n)?>y
Enter the new threshold(0~100)>80
Current remap percentage threshold: 80%
Press Enter key to return
4.
Press Y and Enter to confirm a Threshold change. Then type a number
between 0 and 100 for remap percentage and press Enter.
5.
Press Enter to return to the PDM Threshold submenu.
6.
Press 2 and Enter to specify Error Count.
7.
Press Y and Enter to confirm a Threshold change. Then type an error
number and press Enter.
8.
Press Enter to return to the PDM Threshold submenu.
Logical Drive Operations under
the Maintenance Menu
From the Main Menu, press 6 and Enter to access the Maintenance menu:
PD: physical drive,
SBS: stripe block size, CAP: capacity,
INIT: initialization,
MP: media patrol,
Maintenance activity Monitor: Running
ID
-------------------------------------------------------------------------
1
2
-------------------------------------------------------------------------
Maintenance
1. Maintenance Activity Monitor
2. Migrate Logical Drive
3. Manual Rebuild
4. Manual PDM)
5. Synchronization
6. Redundancy Check
7. Media Patrol
R. Return to Previous Menu
LD: logical drive
RBLD: rebuild,
Name
RAID SBS
LogDrv1
5
LogDrv2
3
RC: redundancy check
PDM: predictive data migration
CAP
64K
239GB
64K
265GB
152
SYNC: synchronization
Operation
Progress
RBLD
27% on 9
None
N/A

Advertisement

Table of Contents
loading

Table of Contents