Buzzer; Temperature; Voltage - Promise Technology VTRAK 15200 User Manual

Table of Contents

Advertisement

VTrak 15200 User Manual
For information on fan replacement, see .page 180.

Buzzer

From the Enclosure Management menu, press 2 and Enter to access the Buzzer
(Beeper). You can also access the Buzzer from the Main menu.
Buzzer
1. Silence Buzzer
2. Enable Buzzer
R. Return to Previous Menu
Please enter your menu choice>2
Enable buzzer(y/n)?>y
Press 2 and Enter to enable or disable the buzzer. Press Y and Enter to confirm.
Press 1 and Enter to silence the buzzer. Press Y and Enter to confirm.
Silence means to cancel the audible alarm for the current event only. If another
event happens, the buzzer will sound again.

Temperature

From the Enclosure Management menu, press 3 and Enter to access
Temperature.
*********************Temperature********************
Temperature # Celsius Fahrenheit
-------------------------------------------------------------------------------
1
2
3
4
5
6
Press Enter key to return
Look for a temperature measurement above the Normal Operational Range. An
elevated temperature can be the result of a failed fan or blocked cooling
passages. Temperature #6 has a higher range because it is located directly
above the main controller board.

Voltage

From the Enclosure Management menu, press 4 and Enter to access Voltage.
27
80
27
80
24
75
23
73
24
75
38
100
136
Normal Operational Range
<= 45 Celsius
<= 45 Celsius
<= 45 Celsius
<= 45 Celsius
<= 45 Celsius
<= 55 Celsius