The iSCSI Node settings screen appears.
3.
Enter the information you want to change and check the boxes of the
features you want to enable. See the list of parameters below.
4.
Click Submit to save your changes. The parameters you set here apply to
both iSCSI ports.
5.
Click the
iSCSI Parameters
•
The node ID number (0 or 1)
•
The node's name – An iSCSI node is identified by its name
•
The node's alias – A user-friendly string associated with an iSCSI Node. Not
a substitute for the iSCSI Name
•
Max outstanding R2T – Sets the maximum number of outstanding ready to
transfer PDUs (a number)
•
First burst length – Maximum length of an unsolicited data sequence (kb)
•
Maximum burst length – Maximum length of a solicited data sequence (kb)
•
Default time to wait – After a dropped connection, the number of seconds to
wait before attempting to reconnect
Chapter 4: Management with WebPAM PRO
link to return to the Controller information window.