What to Do
Caution – If you are using an antistatic wrist strap to protect against electrostatic
discharge, connect it to a properly grounded surface, such as a nearby equipment
rack, or a nearby system that is connected to a power source.
1. Disconnect the AC power cords from the back of the system.
2. Using a Phillips No. 2 screwdriver, remove the external connector faceplate on the
back panel.
The faceplate is secured with seven screws.
3. Using a Phillips No. 2 screwdriver, remove the screw on the centerplane top
stiffener closest to the front of the system.
External connector faceplate
Chapter 6 Servicing Miscellaneous Components
145