Maintenance

Inspection guide

Use this guide in identifying the parts that must be inspected, cleaned, or replaced based on the page count.
If any unsafe conditions exist, find out how serious the hazard could be and if you can continue before you correct the
hazard.
As you service the machine, check for the following:
Damaged, missing, or altered parts, especially in the area of the On/Off switch and the power supply
Damaged, missing, or altered covers, especially in the area of the top cover and the power supply cover
Possible safety exposure from any non-Lexmark attachments
Use the following table to determine when specified parts should be inspected:
PART
MEDIA FEEDERS/TRAYS—ALL
Feed, separator, and pick rollers
Transport rollers
Sensors (photo reflective)
REGISTRATION
Registration roller
IMAGE TRANSFER
Transfer belt paper guide
Sensor (toner density)
Imaging unit maintenance kit:
Transfer belt
Exhaust filter
Ozone filter
Printhead cleaner
DEVELOPER
1
For 500‑sheet trays, if jams still occur after 80K, replace using the spare rollers in the tray compartment.
2
Clean with damp cloth.
3
Clean with brush.
4
Reset 300K Maintenance kit.
5
Reset 600K Maintenance kit.
6
Reset Fuser kit.
7
Clean when fuser is replaced.
8
Clean with dry cloth.
EVERY 50K
1
Clean
2
Clean
3
Clean
2
Clean
2
Clean
‑‑
‑‑
Maintenance
419
EVERY 300K
EVERY 600K
4
Replace
Replace
‑‑
‑‑
‑‑
‑‑
‑‑
‑‑
‑‑
‑‑
‑‑
3
Clean
4
Replace
Replace
EVERY 720K
‑‑
5
‑‑
‑‑
‑‑
‑‑
‑‑
‑‑
5
4021