Remove the six screws (A), remove the diverter bracket, and then remove the sensor actuator (B).
Installation note: Make sure that the ground retainers (A) are correctly installed.

Sensor (duplex pass through 1) removal

1
Remove the duplex transport assembly. See
2
Remove the duplex transport diverter assembly. See
"Duplex transport assembly removal" on page
"Duplex transport diverter assembly removal" on page