Air Cleaner Housing Removal - Honda 2004 CRF250X Service Manual

Hide thumbs Also See for 2004 CRF250X:
Table of Contents

Advertisement

2. Turn the throttle stop screw to obtain
the
smoothest idle:
To decrease idle speed,
turn
the throttle stop
screw counterclockwise.
To increase idle speed, turn the throttle stop
screw clockwise.
3. Adjust the pilot screw to obtain the best off-idle
performance.
TOOl:
Pilot screw
wrench
'04
- '06:
07908-4730002
After
'06:
07KMA-MN90101
and
07PMA-MZ20110
or
07KMA-MN9-Al00
(U.S.A
only)
If the engine runs
rich
exiting a corner, turn the
pilot screw clockwise to lean the mixture.
If the engine runs lean exiting a corner, turn the
pilot screw counterclockwise to richen the mix-
ture.
AIR CLEANER HOUSING
REMOVAL
Remove the following:
-
Seat (page 2-3)
-
Fuel tank (page 2-7)
-
Side covers (page 2-3)
-
Muffler (page 2-8)
-
Battery (page 16-6)
Support the motorcycle using a workstand or equiv-
alent under
the
engine.
Remove the screws and right air cleaner housing
cover.
Loosen the air cleaner connecting boot band screw.