System SP Tables-5

4.5 SYSTEM SP TABLES-5

4.5.1 SP5XXX: MODE

mm/inch Selection
Selects whether mm or inches are used in the display.
Note: After selecting the number, you must turn the main power switch off
5024*
and on.
Europe/Asia model: [0 = mm / 1 = inch]
American model: [0 = mm / 1 = inch]
5045
Accounting Counter
Selects whether the printer counter is displayed on the LCD.
[0-1/0/1]
0: Displays the total counter only.
1: Displays both total counter and printer counter.
5047
Paper Display
Determines whether the tray loaded with paper printed on one side is
displayed.
[0 to 1/1]
0: Not displayed
1: Displayed
Return Time Priority Type
The recovery time of the Basic model is 5 sec. so two settings are provided,
5052
one for energy save priority and one for start time priority.
0: Energy save priority
1: Start time priority