Installation Requirements; Machine Level - Ricoh D017 Service Manual

Table of Contents

Advertisement

2. INSTALLATION

2.1 INSTALLATION REQUIREMENTS

2.1.1 ENVIRONMENT
1.
Temperature Range: 10 °C to 32 °C (50 °F to 89.6 °F)
2.
Humidity Range: 15% to 80% RH
3.
Ambient Illumination: Less than 1,500 lux (do not expose to direct sunlight.)
4.
Ventilation: Room air should turn over at least 30 m
5.
Ambient Dust: Less than 0.10 mg/m
6.
Avoid an area which is exposed to sudden temperature changes. This includes:
Areas directly exposed to cool air from an air conditioner.
Areas directly exposed to heat from a heater.
7.
Do not place the machine in an area where it will be exposed to corrosive gases.
8.
Do not install the machine at any location over 2,000 m (6,500 ft.) above sea level.
9.
Place the copier on a strong and level base. (Inclination on any side should be no more
than 5 mm.)
10. Do not place the machine where it may be subjected to strong vibrations.

2.1.2 MACHINE LEVEL

Front to back: Within 5 mm (0.2") of level
Right to left: Within 5 mm (0.2") of level
D017/D018/D019/D020/D084/D085
3
/hr/person
3
2-1
Installation Requirements
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D019D085D018D020D084