Ricoh D017 Service Manual page 894

Table of Contents

Advertisement

Bit Switches - 1
No
Function
G3/G4 communication
parameter display
5
0: Disabled
1: Enabled
Protocol dump list output after
each communication
6
0: Off
1: On
7
Not used
D361/D510
System Switch 00 (SP No. 1-101-001)
This is a fault-finding aid. The LCD shows the
key parameters (see below). This is normally
disabled because it cancels the CSI display for
the user.
Be sure to reset this bit to 0 after testing.
This is only used for communication
troubleshooting. It shows the content of the
transmitted facsimile protocol signals. Always
reset this bit to 0 after finishing testing.
If system switch 09 bit 6 is at "1", the list is only
printed if there was an error during the
communication.
Do not change the setting.
76
Comments
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D019D085D018D020D084

Table of Contents