Printer Service Tables
1001
Bit Switch
003 Bit Switch 3
bit 0
DFU
bit 1
DFU
bit 2
[PCL5e/c]: Legacy HP compatibility
Enable: Uses the same left margin as older HP models such as
HP4000/HP8000.
In other words, the left margin defined in the job (usually "<ESC>*r0A")
will be changed to "<ESC>*r1A"
bit 3
DFU
bit 4
DFU
bit 5
DFU
bit 6
DFU
bit 7
DFU
1001
Bit Switch
004 Bit Switch 4 DFU
D017/D018/D019/D020/D084/D085
0: Disable
4-230
0
1
-
-
-
-
1: Enable
-
-
-
-
-
-
-
-
-
-
-
-
SM Appendix