Rev. 01/25/2010
This bitsw determines the timing of the PJL USTATUS JOB END sent
when multiple collated copies are being printed.
0 (default): JOB END is sent by the device to the client after the first copy
has completed printing. This causes the page counter to be incremented
bit 7
after the first copy and then again at the end of the job.
1: JOB END is sent by the device to the client after the last copy has
finished printing. This causes the page counter to be incremented at the
end of each job.
1001
Bit Switch
007 Bit Switch 7
Print path
Enable: Simplex pages (in mixed simplex/duplex PS/PCL5 jobs only) and
bit 0
the last page of an odd paged duplex job (PS, PCL5, PCL6), are always
routed through the duplex unit. Not having to switch paper paths increases
the print speed slightly.
bit 1
DFU
bit 2
DFU
bit 3
DFU
bit 4
DFU
bit 5
DFU
bit 6
DFU
bit 7
DFU
SM Appendix
0
Disable
-
-
-
-
-
-
-
4-233
D017/D018/D019/D020/D084/D085
Printer Service Tables
1
Enable
-
-
-
-
-
-
-