Ricoh D017 Service Manual page 459

Table of Contents

Advertisement

System SP Tables-2
TD Sensor Manual Setting
2930*
Adjusts the TD sensor output. DFU
[0 to 5 / 0.0V / 0.05V/step]
TD (V/wt%) Setting
Adjusts the TD sensor sensitivity (coefficient: S) for toner density control.
2931*
DFU
[0.01 to 1.50 / 0.4 / 0.01/step]
Toner Density Control Level
Adjusts the toner density control threshold level.
2932*
[0 = Normal / 1 = Dark / 2 = Light / 3 = Darker / 4 = Lighter]
Use this SP when you want to adjust the image density.
ID Sensor Control Correction
2933*
Adjusts the ID sensor control coefficient. DFU
[0.5 to 3 / 1 / 0.1/step]
2934*
ID Sensor PWM Setting
1 Display
Upper Limit Correction
3
Corrects the upper limit of the PWM for the ID sensor LED. DFU
[0 to 255 / 50 / 1/step]
ID Sensor Initialization
Performs the ID sensor initial setting.
2935
Press Execute on the touch panel to start. Perform this setting after
replacing or cleaning the ID sensor.
D017/D018/D019/D020/D084/D085
Displays the PWM of the ID Sensor LED.
4-26