Inspecting, Maintaining, and Testing the Battery (continued)
Charging the Battery
Electrical System: Service and Repairs
B. If you charge the battery, apply a 150 A load for 15 seconds to remove
the surface charge. Use a battery load tester following the manufacturer's
instructions.
C. Ensure that the battery terminals are free of corrosion.
D. If possibe, measure the electrolyte temperature of the center cell.
E. Connect a battery load tester to the battery terminals following the
manufacturer's instructions. Connect a digital multimeter to the battery
terminals
F. Apply a test load of 1/2 the cold cranking amperage rating of the battery;
refer to
Battery Specifications (page
G. Take a test voltage reading while still under load after 15 seconds, then
immediately remove the load.
H. Use
Minimum Voltage (page 6–30)
the center cell electrolyte temperature reading.
I.
If the test voltage is below the minimum, replace the battery. If the test
voltage is at or above the minimum, return the battery to service.
Battery Charge Level
Battery Charge Level
100%
75%
50%
25%
0%
6–28).
to determine the minimum voltage for
Specific Gravity
1.265
1.225
1.190
1.155
1.120
Page 6–32
Open Circuit Voltage
12.68
12.45
12.24
12.06
11.89
Field Pro® 6040
22267SL Rev A