v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine
which components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
3818006
Opposite bank CRTM capsule signature
invalid
3818007
CRTM update capsule signature invalid
3828004
AEM power capping disabled
8007010
A resource I/O limitation event has
occurred.
Action
1. Switch the server firmware bank to the backup
bank (see "Starting the backup server firmware"
on page 409).
2. Run the Setup utility, select Load Default
Settings, and save the settings.
3. Switch the bank back to the primary bank.
4. (Trained service technician only) Replace the
system board.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
1. Check the settings and the event logs.
2. Make sure that the Active Energy Manager
feature is enabled in the Setup utility. Select
System Settings, Power, Active Energy Manager,
and Capping Enabled.
3. Update the server firmware to the latest level (see
"Updating the firmware" on page 397).
To allow more PCIe space, choose one of the
following:
1. Change the MM configuration setting to 1 GB
a. Run the Setup utility (see "Using the Setup
utility" on page 402), select Devices and I/O
Ports .
b. Set MMConfigBase to 1 GB.
2. Enable PCI 64-bit Resource.
a. Run the Setup utility (see "Using the Setup
utility" on page 402), and select Devices and
I/O Ports –> PCI 64-bit Resource.
b. Enable PCI 64-bit Resource.
47
Chapter 3. Diagnostics