IBM x3690 X5 Service Manual page 242

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

Table 11. IMM error messages detected when MAX5 is attached to the server (continued)
Event ID
80010b01-1881xxxx
8003010c-1881xxxx
806f070c-1881xxxx
224
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Message
Numeric sensor MEU
Chipset Temp going high
(upper non-recoverable) has
asserted.
Sensor Lane FailoverMEU
has asserted
Configuration error for
Memory Device n in
Memory Expansion Unit 1
on subsystem System
Memory has deasserted
Memory Logging Limit
removed for Memory Device
n in Memory Expansion Unit
1 on subsystem System
Memory
Uncorrectable error recovery
detected for Memory Device
n in Memory Expansion Unit
1 on subsystem System
Memory
MEU Bank n Status on
subsystem System Memory
throttled
Severity Description
Error
MAX5 chipset
temperature
Overspec.
Info
A memory lane
failover event has
occurred.
Info
MAX5 memory
expansion module
configuration error
deasserted.
Info
MAX5 memory
expansion module
memory logging
limit deasserted.
Info
MAX5 memory
expansion module
memory Bank n error
recovered.
Info
MAX5 memory
expansion module
throttling asserted.
Action
1. Make sure that
the ambient
temperature is
within the
product
specifications for
the MAX5 and
the host server.
2. Make sure that
the fans are
operating
properly, there
are no
obstructions to
the airflow, the
air baffles are
installed correctly,
and the server
cover is installed
and completely
closed (see
"Replacing the
server top cover"
on page 265).
3. (Trained service
technician) Make
sure that all heat
sinks are properly
installed on the
host server.
No action;
information only.
No action;
information only.
No action;
information only.
No action;
information only.
No action;
information only.

Advertisement

Table of Contents
loading

Table of Contents