IBM x3690 X5 Service Manual page 204

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

Table 10. System x3690 X5 IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service
technician.
Event ID
Message
800b050a-1e83xxxx
Non-redundant:Insufficient Resources
for [RedundancySetElementName] has
asserted
800b050a-1e84xxxx
Non-redundant:Insufficient Resources
for [RedundancySetElementName] has
asserted
800b050a-1e85xxxx
Non-redundant:Insufficient Resources
for [RedundancySetElementName] has
asserted
806f0007-0301xxxx
The Processor CPU n Status has Failed
806f0007-0302xxxx
with IERR.(n = microprocessor
number)
186
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Severity
Description
Error
Cooling zone alert.
Error
Cooling zone alert.
Error
Cooling zone alert.
Error
A processor failed -
IERR condition has
occurred.
Action
Cooling zone 3 error:
Replace fan 3.
Cooling zone 4 error:
Replace fan 4.
Cooling zone 5 error:
Replace fan 5.
1. Make sure that the
latest levels of firmware
and device drivers are
installed for all adapters
and standard devices,
such as Ethernet, SCSI,
and SAS.
Important: Some cluster
solutions require
specific code levels or
coordinated code
updates. If the device is
part of a cluster
solution, verify that the
latest level of code is
supported for the
cluster solution before
you update the code.
2. Update the firmware
(UEFI and IMM) to the
latest level "Updating
the firmware" on page
397).
3. Run the DSA program
for the hard disk drives
and other I/O devices.
4. Reseat the adapter.
5. Replace the adapter.
6. (Trained service
technician only) Replace
microprocessor n.
7. (Trained service
technician only) Replace
the system board.
(n = microprocessor
number)

Advertisement

Table of Contents
loading

Table of Contents