Table 10. System x3690 X5 IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service
technician.
Event ID
Message
80010902-0701xxxx
Numeric sensor Planar 3.3V going
high (upper critical) has asserted.
80010902-0701xxxx
Numeric sensor Planar 5V going high
(upper critical) has asserted.
80010903-1501xxxx
Numeric sensor FG 1PS going high
(upper critical) has asserted.
80010903-1502xxxx
Numeric sensor FG 2PS going high
(upper critical) has asserted.
80010903-1503xxxx
Numeric sensor FG 3PS going high
(upper critical) has asserted.
170
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Severity
Description
Error
An upper critical
sensor going high
has asserted.
Error
An upper critical
sensor going high
has asserted.
Warning
Power supply fuel
gage warning.
Warning
Power supply fuel
gage warning.
Warning
Power supply fuel
gage warning.
Action
(Trained service technician
only) Replace the system
board.
(Trained service technician
only) Replace the system
board.
1. The management
controller has detected a
sensor transitioned to
critical from less severe
on the power supply 1.
2. Make sure that the
power supply is
installed correctly (see
"Replacing a hot-swap
power supply" on page
326) . Make sure that no
error LEDs are lit on the
power supply and that
all power supplies have
the green LEDs lit.
1. The management
controller has detected a
sensor transitioned to
critical from less severe
on the power supply 2.
2. Make sure that the
power supply is
installed correctly (see
"Replacing a hot-swap
power supply" on page
326). Make sure that no
error LEDs are lit on the
power supply and that
all power supplies have
the green LEDs lit.
1. The management
controller has detected a
sensor transitioned to
critical from less severe
on the power supply 3.
2. Make sure that the
power supply is
installed correctly (see
"Replacing a hot-swap
power supply" on page
326). Make sure that no
error LEDs are lit on the
power supply and that
all power supplies have
the green LEDs lit.