IBM x3690 X5 Service Manual page 205

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

Table 10. System x3690 X5 IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service
technician.
Event ID
Message
806f0021-2582xxxx
Fault in slot System board on system
%1.(%1 =
CIM_ComputerSystem.ElementName)
All PCI Error
One of PCI
Severity
Description
Error
Action
1. Check the riser-card
LEDs.
2. Reseat the affected
adapters and riser card.
3. Update the server
firmware (UEFI and
IMM) and adapter
firmware.
Important: Some cluster
solutions require
specific code levels or
coordinated code
updates. If the device is
part of a cluster
solution, verify that the
latest level of code is
supported for the
cluster solution before
you update the code.
4. Make sure that the
adapter is on the
serverproven list.
5. Remove both adapters.
6. Replace the PCIe
adapter.
7. Replace the riser card.
8. (Trained service
technician only) Replace
the system board.
187
Chapter 3. Diagnostics

Advertisement

Table of Contents
loading

Table of Contents