IBM x3690 X5 Service Manual page 324

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

10. Turn on the peripheral devices and the server.
306
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
6. Reconnect cables to the adapter. Be sure to route the signal cables through the
SAS cable guide and up and over the rear of the microprocessor air baffle;
then, through the loops on the scalability connector cover and then to the
adapter (see the following illustration). Use the cable ties (as shown in the
illustration) that come with the drive backplane to secure the SAS cables so
that they do not get in the way or get damaged.
Cable ties
Microprocessor
air baffle
SAS signal cable
7. Replace the cover (see "Replacing the server top cover" on page 265).
8. Slide the server in the rack.
9. Reconnect the power cord and any cables that you removed.
Cable tie
loops
SAS signal
cable guide
Scalability
connector
cover
Adapter

Advertisement

Table of Contents
loading

Table of Contents