Table 10. System x3690 X5 IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service
technician.
Event ID
Message
806f0207-0301xxxx
The Processor CPU n Status has Failed
806f0207-0302xxxx
with FRB1/BIST condition.(n =
microprocessor number)
806f050d-040Xxxxx
Array
[ComputerSystemElementName] is in
critical condition.
Severity
Description
Error
A processor failed -
FRB1/BIST
condition has
occurred.
Warning
Drive array is in
critical condition.
Action
1. Check for a server
firmware update.
Important: Some cluster
solutions require
specific code levels or
coordinated code
updates. If the device is
part of a cluster
solution, verify that the
latest level of code is
supported for the
cluster solution before
you update the code.
2. Make sure that the
installed
microprocessors are
compatible with each
other (see "Replacing a
microprocessor and heat
sink" on page 351 for
information about
microprocessor
requirements).
3. (Trained service
technician only) Reseat
microprocessor n.
4. (Trained service
technician only) Replace
microprocessor n.
(n = microprocessor
number)
The drive array specified in
the error message (1-32) is
in critical condition.
Replace the drive.
191