Table 11. IMM error messages detected when MAX5 is attached to the server (continued)
Event ID
80070208-1881xxxx
81070208-1881xxxx
80070208-1881xxxx
81070208-1881xxxx
80070208-1881xxxx
240
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Message
Sensor MEU PS2 Fan has
transitioned to critical from a
less severe state
Sensor MEU PS2 Therm has
transitioned to a less severe
state from critical
Sensor MEU PS2 Therm has
transitioned to critical from a
less severe state
Sensor MEU PS1 Fan has
transitioned to a less severe
state from critical
Sensor MEU PS1 Fan has
transitioned to critical from a
less severe state
Severity Description
Error
MAX5 memory
expansion module
power supply 2 error
detected.
Info
MAX5 memory
expansion module
power supply 2 is
now normal.
Error
MAX5 memory
expansion module
power supply 2 error
detected.
Info
MAX5 memory
expansion module
power supply 1 is
now normal.
Error
MAX5 memory
expansion module
power supply 1 error
detected.
Action
1. Check MAX5
memory
expansion
module LEDs.
2. Check MAX5
memory
expansion
module power
supply 2 LEDs.
3. Replace the
MAX5 memory
expansion
module power
supply 2.
No action;
information only.
1. Check MAX5
memory
expansion
module LEDs.
2. Check MAX5
memory
expansion
module power
supply 2 LEDs.
3. Replace the
MAX5 memory
expansion
module power
supply 2.
No action;
information only.
1. Check MAX5
memory
expansion
module LEDs.
2. Check MAX5
memory
expansion
module power
supply 1 LEDs.
3. Replace the
MAX5 memory
expansion
module power
supply 1.