IBM x3690 X5 Service Manual page 238

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

Table 10. System x3690 X5 IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service
technician.
Event ID
Message
Flash of %1 from %2 failed for user
%3.(%1 =
CIM_ManagedElement.ElementName;
%2 = Web or LegacyCLI; %3 = user
ID)
The Chassis Event Log (CEL) on
system %1 is 75% full.(%1 =
CIM_ComputerSystem.ElementName)
40000025-00000000
The Chassis Event Log (CEL) on
system %1 is 100% full.(%1 =
CIM_ComputerSystem.ElementName)
40000027-00000000
%1 Platform Watchdog Timer expired
for %2.(%1 = OS Watchdog or Loader
Watchdog; %2 = OS Watchdog or
Loader Watchdog)
IMM Test Alert Generated by %1.(%1
= user ID)
40000029-00000000
Security: Userid: ' had %2 login
failures from an SSH client at IP
address %3.(%1 = user ID; %2 =
MaximumSuccessiveLoginFailures
(currently set to 5 in the firmware);
%3 = IP address, xxx.xxx.xxx.xxx)
220
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Severity
Description
Info
An attempt to
update a firmware
component from
the interface and IP
address has failed.
Info
The IMM event log
is 75% full. When
the log is full, older
log entries are
replaced by newer
ones.
Info
The IMM event log
is full. When the
log is full, older log
entries are replaced
by newer ones.
Error
A Platform
Watchdog Timer
Expired event has
occurred.
Info
A user has
generated a test
alert from the IMM.
Error
A user has
exceeded the
maximum number
of unsuccessful
login attempts from
SSH and has been
prevented from
logging in for the
lockout period.
Action
Try to update the firmware
again.
To avoid losing older log
entries, save the log as a
text file and clear the log.
To avoid losing older log
entries, save the log as a
text file and clear the log.
1. Reconfigure the
watchdog timer to a
higher value.
2. Make sure that the IMM
Ethernet over USB
interface is enabled in
System Settings in the
Setup utility. (see
"Using the Setup
utility" on page 402 for
more information).
3. Reinstall the RNDIS or
cdc_ether device driver
for the operating
system.
4. Disable the watchdog.
5. Check the integrity of
the installed operating
system.
No action; information only.
1. Make sure that the
correct login ID and
password are being
used.
2. Have the system
administrator reset the
login ID or password.

Advertisement

Table of Contents
loading