IBM x3690 X5 Service Manual page 176

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

Table 8. DSA messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine
which components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
Trained service technician.
v Go to the IBM support Web site at http://www.ibm.com/supportportal/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
217-900-xxx
SAS/SATA
Hard Drive
405-901-xxx
BroadCom
Ethernet
Device
158
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
State
Description
Disk Drive
Failed
The hard drive
Test
self-test was
canceled.
Test
Failed
Control
Registers
Action
1. Reseat all hard disk drive backplane
connections at both ends.
2. Reseat the all drives.
3. Run the test again.
4. Make sure that the firmware is at the
latest level.
5. Run the test again.
6. If the failure remains, go to the IBM Web
site for more troubleshooting information
at http://www.ibm.com/systems/
support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
1. Make sure that the component firmware
is at the latest level. The installed
firmware level is shown in the DSA event
log in the Firmware/VPD section for this
component. For more information, see
"Updating the firmware" on page 397.
2. Run the test again.
3. Replace the component that is causing the
error. If the error is caused by an adapter,
replace the adapter. Check the PCI
Information and Network Settings
information in the DSA event log to
determine the physical location of the
failing component.
4. If the failure remains, go to the IBM Web
site for more troubleshooting information
at http://www.ibm.com/systems/
support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
Continued on the next page.

Advertisement

Table of Contents
loading

Table of Contents