c. Reinstall any SAS cables that you removed earlier back into the SAS cable
guide. Be sure to route the signal cables through the SAS cable guide and
up and over the rear of the microprocessor air baffle; then, through the
loops on the scalability connector cover and then to the adapter (see the
following illustration). Use the cable ties (as shown in the illustration) that
come with the drive backplane to secure the SAS cables so that they do not
get in the way or get damaged.
Cable ties
Microprocessor
air baffle
3. Reinstall the fan cage assembly (see "Replacing the fan cage assembly" on page
332).
4. Reinstall the cover (see "Replacing the server top cover" on page 265).
5. Slide the server into the rack.
6. Reconnect the power cords and any cables that you removed.
Cable tie
loops
SAS signal cable
SAS signal
cable guide
Chapter 5. Removing and replacing components
Scalability
connector
cover
Adapter
273