Table 11. IMM error messages detected when MAX5 is attached to the server (continued)
Event ID
806f0a0c-258cxxxx
806f0a0c-258dxxxx
81070608-1881xxxx
Message
An Over-Temperature
Condition has been detected
on the
[PhysicalMemoryElementName]
on Subsystem
[MemoryElementName].
An Over-Temperature
Condition has been detected
on the
[PhysicalMemoryElementName]
on Subsystem
[MemoryElementName].
Sensor MEU PS2 VCO has
deasserted the transition to
non-recoverable
Severity Description
Error
MEU Bank 5/6
:Over-temperature
condition.
Error
MEU Bank 7/8
:Over-temperature
condition.
Info
MAX5 memory
expansion module
power supply 2 is
now normal.
Action
1. Check Retain
TIPs for known
issues.
2. Check the IMM
event log for any
fan or cooling
related issues or
power related
issues.
3. Make sure that
the airflow at the
front and rear of
the chassis is not
obstructed and
that the fillers are
in place and
correctly
installed.
4. Make sure that
the room
temperature is
within operating
specifications.
1. Check Retain
TIPs for known
issues.
2. Check the IMM
event log for any
fan or cooling
related issues or
power related
issues.
3. Make sure that
the airflow at the
front and rear of
the chassis is not
obstructed and
that the fillers are
in place and
correctly
installed.
4. Make sure that
the room
temperature is
within operating
specifications.
No action;
information only.