Replacing The Bezel; Removing The Memory Tray - IBM x3690 X5 Service Manual

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

6. Pull the top of the bezel out slightly; then, rotate it downward until the tabs on

Replacing the bezel

To install the bezel, complete the following steps:
1. Insert the tabs on the bottom of the bezel into the holes on the chassis.
2. Rotate the bezel upward to the server and reinstall the bezel screws.
3. Reinstall the hard disk drives and drive bay filler panels into the drive bays.
4. Install the cover (see "Replacing the server top cover" on page 265).
5. Reconnect the power cords and any cables that you removed.
6. Slide the server into the rack.
7. Turn on the peripheral devices and the server.

Removing the memory tray

To remove the memory tray, complete the following steps:
1. Read the safety information and installation guidelines, see "Safety" on page vii
2. Turn off the server (see "Turning off the server" on page 17) and all attached
3. If the server has been installed in a rack, slide the server out from the rack
4. Remove the top cover (see "Removing the server top cover" on page 264).
5. If any remote RAID adapter batteries are stored in the RAID battery trays on
266
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Bezel
screws
the bottom of the bezel disengages from the chassis and set it aside.
Bezel
screws
and "Installation guidelines" on page 261.
peripheral devices. Disconnect all power cords; then, disconnect all external
cables as necessary to replace the device.
enclosure.
top of the memory tray, remove the battery tray from the memory tray and set
it aside; then, grasp the memory tray handle by the blue touch points and
rotate it all the way up (this disengages the memory tray from the connectors
on the system board).
Bezel
Bezel

Advertisement

Table of Contents
loading

Table of Contents