IBM x3690 X5 Service Manual page 256

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

Table 11. IMM error messages detected when MAX5 is attached to the server (continued)
Event ID
80070608-1881xxxx
81070608-1881xxxx
80070608-1881xxxx
81070608-1881xxxx
80070608-1881xxxx
238
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Message
Sensor MEU PS1 12V OC
has transitioned to
non-recoverable
Sensor MEU PS2 12V UV
has deasserted the transition
to non-recoverable
Sensor MEU PS2 12V UV
has transitioned to
non-recoverable
Sensor MEU PS1 12V UV
has deasserted the transition
to non-recoverable
Sensor MEU PS1 12V UV
has transitioned to
non-recoverable
Severity Description
Error
MAX5 memory
expansion module
power supply 1 error
detected.
Info
MAX5 memory
expansion module
power supply 2 is
now normal.
Error
MAX5 memory
expansion module
power supply 2 error
detected.
Info
MAX5 memory
expansion module
power supply 1 is
now normal.
Error
MAX5 memory
expansion module
power supply 1 error
detected.
Action
1. Check MAX5
memory
expansion
module LEDs.
2. Check MAX5
memory
expansion
module power
supply 1 LEDs.
3. Replace the
MAX5 memory
expansion
module power
supply 1.
No action;
information only.
1. Check MAX5
memory
expansion
module LEDs.
2. Check MAX5
memory
expansion
module power
supply 2 LEDs.
3. Replace the
MAX5 memory
expansion
module power
supply 2.
No action;
information only.
1. Check MAX5
memory
expansion
module LEDs.
2. Check MAX5
memory
expansion
module power
supply 1 LEDs.
3. Replace the
MAX5 memory
expansion
module power
supply 1.

Advertisement

Table of Contents
loading

Table of Contents