Table 11. IMM error messages detected when MAX5 is attached to the server (continued)
Event ID
81070208-1881xxxx
80070208-1881xxxx
80080004-1d06xxxx
80080004-1d07xxxx
Message
Sensor MEU PS1 Therm has
transitioned to a less severe
state from critical
Sensor MEU PS1 Therm has
transitioned to critical from a
less severe state
Device MEU Fan 1 has been
removed from unit
[PhysicalPackageElementName]
Device MEU Fan 2 has been
removed from unit
[PhysicalPackageElementName]
Severity Description
Info
MAX5 memory
expansion module
power supply 1 is
now normal.
Error
MAX5 memory
expansion module
power supply 1 error
detected.
Warning MEU Fan 1 is no
longer detected or is
not installed.
Warning MEU Fan 2 is no
longer detected or is
not installed.
Action
No action;
information only.
1. Check MAX5
memory
expansion
module LEDs.
2. Check MAX5
memory
expansion
module power
supply 1 LEDs.
3. Replace the
MAX5 memory
expansion
module power
supply 1.
1. Install the fan, if
missing.
2. Reseat the fan
with the lit error
LED.
3. Replace the fan if
the problem
remains.
4. (Trained service
technician only)
Replace system
board.
1. Install the fan, if
missing.
2. Reseat the fan
with the lit error
LED.
3. Replace the fan if
the problem
remains.
4. (Trained service
technician only)
Replace system
board.
241
Chapter 3. Diagnostics