IBM x3690 X5 Service Manual page 203

Hide thumbs Also See for x3690 X5:
Table of Contents

Advertisement

Table 10. System x3690 X5 IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service
technician.
Event ID
Message
800b010a-1e81xxxx
Redundancy Cooling Zone 1 has been
800b010a-1e82xxxx
reduced.
800b010a-1e83xxxx
800b010a-1e84xxxx
800b010a-1e85xxxx
800b010a-1e86xxxx
Sensor RAID Error has transitioned to
critical from a less severe state.
800b010c-2581xxxx
Redundancy Bckup Mem Status has
been reduced.
800b0208-1381xxxx
Redundancy Degraded for Power Unit
has asserted.
800b0308-1381xxxx
Non-redundant:Sufficient Resources
from Redundancy Degraded or Fully
Redundant for
[RedundancySetElementName] has
asserted
800b050a-1e81xxxx
Non-redundant:Insufficient Resources
for [RedundancySetElementName] has
asserted
800b050a-1e82xxxx
Non-redundant:Insufficient Resources
for [RedundancySetElementName] has
asserted
Severity
Description
Error
Redundancy has
been lost and is
insufficient to
continue operation.
Error
A sensor has
changed to Critical
state from a less
severe state.
Error
Redundancy has
been lost and is
insufficient to
continue operation.
Warning
Redundancy
degraded has
asserted.
Info
Redundancy set has
transitioned from
redundancy
degraded or fully
redundant to
non-
redundant:sufficient.
Error
Cooling zone alert.
Error
Cooling zone alert.
Action
1. Make sure that the
connectors on fans 1
and 2 are not damaged.
2. Make sure that the fan 1
and 2 connectors on the
system board are not
damaged.
3. Make sure that the fans
are correctly installed.
4. Reseat the fans.
5. Replace the fans.
1. Check the hard disk
drive amber status
LEDs to identify the
failed hard disk drive or
check the RAID
controller system
management software
event logs.
2. Reseat the hard disk
drive for which the
status LED is lit.
3. Replace the defective
hard disk drive.
1. Check the system-event
log for DIMM failure
events (uncorrectable or
PFA) and correct the
failures.
2. Re-enable mirroring in
System Settings in the
Setup utility (see "Using
the Setup utility" on
page 402 for more
information).
Check the power supply to
make sure that the power is
connected correctly.
The power supplies are
non-redundant.
Cooling zone 1 error:
Replace fan 1.
Cooling zone 2 error:
Replace fan 2.
185
Chapter 3. Diagnostics

Advertisement

Table of Contents
loading