Table 10. System x3690 X5 IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service
technician.
Event ID
Message
806f070c-2581xxxx
Memory DIMM Configuration Error
for One of the DIMMs on Memory
Subsystem One of the DIMMs.
Memory uncorrectable error detected
for Memory Device n on subsystem
System Memory.(n = DIMM number)
Memory Logging Limit Reached for
Memory Device n on subsystem
System Memory.(n = DIMM number)
Memory DIMM Configuration Error
for Memory Device n on subsystem
System Memory.(n = DIMM number)
Severity
Description
Error
A DIMM
configuration error
has occurred.
Error
A memory
uncorrectable error
has occurred.
Error
The memory
logging limit has
been reached.
Error
A DIMM
configuration error
has occurred.
Action
Make sure that DIMMs are
installed in the correct
sequence and have the
same size, type, speed, and
technology.
1. If the server failed the
POST memory test,
reseat the DIMMs.
2. Replace any DIMM that
is indicated by a lit
error LED.
Note: You do not have
to replace DIMMs by
pairs.
3. Run the Setup utility to
enable all the DIMMs.
4. Run the DSA memory
test.
5. (Trained service
technician only) Replace
the system board.
1. Update the server
firmware to the latest
level (see "Updating the
firmware" on page 397).
Important: Some cluster
solutions require
specific code levels or
coordinated code
updates. If the device is
part of a cluster
solution, verify that the
latest level of code is
supported for the
cluster solution before
you update the code.
2. Reseat the DIMMs and
run the DSA memory
test.
3. Replace any DIMM that
is indicated by a lit
error LED.
Make sure that DIMMs are
installed in the correct
sequence and have the
same size, type, speed, and
technology.
209
Chapter 3. Diagnostics