Table 10. System x3690 X5 IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service
technician.
Event ID
Message
806f0125-1f05xxxx
[ManagedElementName] detected as
absent.
806f0125-1f06xxxx
[ManagedElementName] detected as
absent.
806f020d-040Xxxxx
Failure Predicted on drive
[StorageVolumeElementName] for
array
[ComputerSystemElementName].
806f0223-2101xxxx
Powering off system
[ComputerSystemElementName]
initiated by [WatchdogElementName].
806f0308-0a01xxxx
PS n Status has lost input (n = power
806f0308-0a02xxxx
supply number)
806f0308-0a03xxxx
806f0308-0a04xxxx
806f0323-2101xxxx
Power cycle of system
[ComputerSystemElementName]
initiated by watchdog
[WatchdogElementName].
Severity
Description
Info
The management
controller has
detected a Managed
Element is Absent.
Info
The management
controller has
detected a Managed
Element is Absent.
Warning
Drive predictive
failure analysis
warning.
Info
The IPMI Watchdog
Timer has expired.
The system was
powered off.
Info
Power supply n is
normal.
Info
The IPMI Watchdog
Timer has power
cycled the system.
Action
1. Make sure that the
memory expansion
module LED cable is
properly seated and
connected.
2. Replace the memory
expansion module LED
cable.
1. Make sure that the
memory expansion
module fan cable is
properly seated and
connected.
2. Replace the memory
expansion module fan
cable.
The drive specified by
[storageVolumeElement
Name] (0-31) is predicted to
fail. Replace the drive as
soon as possible
Information only; no action
is required.
No action; informational
only.
Information only; no action
is required.
201
Chapter 3. Diagnostics