Table 10. System x3690 X5 IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service
technician.
Event ID
Message
806f050c-2581xxxx
Memory Logging Limit Reached for
DIMM All DIMMs on Memory
Subsystem All DIMMs.
Severity
Description
Error
The memory
logging limit has
been reached.
Action
1. Check IBM support site
for an applicable
RETAIN tip or firmware
update that applies to
this memory error.
2. At the next maintenance
opportunity, swap the
affected DIMM (as
indicated by the light
path LED or event log
entry) to a different
memory channel. See
"Replacing a memory
module" on page 296
for information on
DIMM population
sequence.
3. If the PFA re-occurs (on
the same DIMM),
replace the affected
DIMM as indicated by
the light path LED or
event log entry (check
for previous history of
PFA).
4. If the problem remains
with the same DIMM
connector, inspect the
DIMM connector for
debris or damage. If the
DIMM connector is
damaged, (train
technician only) replace
the system board.
207