Table 10. System x3690 X5 IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192," on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service
technician.
Event ID
Message
80070608-1403xxxx
Sensor CPU2 VRD has transitioned to
non-recoverable
80070608-1404xxxx
Sensor SAS VRD has transitioned to
non-recoverable
80070608-1405xxxx
Sensor VRD 3.3V has transitioned to
non-recoverable
80070608-1406xxxx
Sensor 5V Power Good has
transitioned to non-recoverable
80070608-0a01xxxx
Sensor PS n VCO has transitioned to
80070608-0a02xxxx
non-recoverable (n = power supply
80070608-0a03xxxx
number)
80070608-0a04xxxx
80070608-0a01xxxx
Sensor PS n 12V OC has transitioned
80070608-0a02xxxx
to non-recoverable (n = power supply
80070608-0a03xxxx
number)
80070608-0a04xxxx
80070608-0a01xxxx
Sensor PS n 12V OV has transitioned
80070608-0a02xxxx
to non-recoverable (n = power supply
80070608-0a03xxxx
number)
80070608-0a04xxxx
80070608-0a01xxxx
Sensor PS n 12V UV has transitioned
80070608-0a02xxxx
to non-recoverable (n = power supply
80070608-0a03xxxx
number)
80070608-0a04xxxx
180
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Severity
Description
Error
A VRD error is
detected.
Error
A VRD error is
detected.
Error
A VRD error is
detected.
Error
Error
An error has been
detected for Power
supply n.
Error
An error has been
detected for Power
supply n.
Error
An error has been
detected for Power
supply n.
Error
An error has been
detected for Power
supply n.
Action
1. Update the following
firmware to the version
indicated below:
v UEFI to version 1.75
or later
v FPGA to version 1.23
or later
v IMM to version 1.33
or later
v DSA to version 9.21
or later
2. (Trained service
technician only) Replace
the system board.
(Trained service technician
only) Replace the system
board.
(Trained service technician
only) Replace the system
board.
(Trained service technician
only) Replace the system
board.
1. Check the power supply
LEDs.
2. Reseat the power
supply.
3. Replace the power
supply
1. Check the power supply
LEDs.
2. Check for a current
overload in the server.
3. Reseat the power
supply.
4. Replace the power
supply
1. Check the power supply
LEDs.
2. Reseat the power
supply.
3. Replace the power
supply
1. Check the power supply
LEDs.
2. Reseat the power
supply.
3. Replace the power
supply