Table 141 SNMP Interface Traps
O PT IO N
O BJEC T L ABEL
linkup
linkUp
linkdown
linkDown
lldp
lldpRemTablesChange
transceiver-ddm
zyTransceiverDdmiTemperature
OutOfRange
zyTransceiverDdmiTxPowerOutO
fRange
zyTransceiverDdmiRxPowerOutO
fRange
zyTransceiverDdmiVoltageOutO
fRange
zyTransceiverDdmiTxBiasOutOfR
ange
zyTransceiverDdmiTemperature
OutOfRangeRecovered
zyTransceiverDdmiTxPowerOutO
fRangeRecovered
zyTransceiverDdmiRxPowerOutO
fRangeRecovered
zyTransceiverDdmiVoltageOutO
fRangeRecovered
zyTransceiverDdmiTxBiasOutOfR
angeRecovered
Storm-control
zyPortStormControlTrap
Chapter 34 Access Control
O BJEC T ID
1.3.6.1.6.3.1.1.5.4
1.3.6.1.6.3.1.1.5.3
1.0.8802.1.1.2.0.0.1
1.3.6.1.4.1.890.1.15.3.84.3.1
1.3.6.1.4.1.890.1.15.3.84.3.2
1.3.6.1.4.1.890.1.15.3.84.3.3
1.3.6.1.4.1.890.1.15.3.84.3.4
1.3.6.1.4.1.890.1.15.3.84.3.5
1.3.6.1.4.1.890.1.15.3.84.3.6
1.3.6.1.4.1.890.1.15.3.84.3.7
1.3.6.1.4.1.890.1.15.3.84.3.8
1.3.6.1.4.1.890.1.15.3.84.3.9
1.3.6.1.4.1.890.1.15.3.84.3.10
1.3.6.1.4.1.890.1.15.3.78.2.1
GS1350 Series User's Guide
282
DESC RIPT IO N
This trap is sent when the Ethernet link
is up.
This trap is sent when the Ethernet link
is down.
The trap is sent when entries in the
remote database have any updates.
Link Layer Discovery Protocol (LLDP),
defined as IEEE 802.1ab, enables LAN
devices that support LLDP to
exchange their configured settings.
This helps eliminate configuration
mismatch issues.
This trap is sent when the transceiver
temperature is above or below the
normal operating range.
This trap is sent when the transmitted
optical power is above or below the
normal operating range.
This trap is sent when the received
optical power is above or below the
normal operating range.
This trap is sent when the transceiver
supply voltage is above or below the
normal operating range.
This trap is sent when the transmitter
laser bias current is above or below
the normal operating range.
This trap is sent when the transceiver
temperature is recovered from the
out of normal operating range.
This trap is sent when the transmitted
optical power is recovered from the
out of normal operating range.
This trap is sent when the received
optical power is recovered from the
out of normal operating range.
This trap is sent when the transceiver
supply voltage is recovered from the
out of normal operating range.
This trap is sent when the transmitter
laser bias current is recovered from
the out of normal operating range.
This trap is sent when storm control is
detected on a specific port. A packet
filter action has been applied on the
interface.