The following table describes the labels in this screen.
Table 55 Advanced Application > VLAN: Port Based VLAN Setup
L ABEL
DESC RIPT IO N
Setting Wizard
Choose
All c o nne c te d
All c o nne c te d
LANs. All incoming and outgoing ports are selected. This option is the most flexible but also the
least secure.
Po rt iso la tio n
cannot communicate with each other. All incoming ports are selected while only the CPU
outgoing port is selected. This option is the most limiting but also the most secure.
After you make your selection, click
mentioned above. You can still customize these settings by adding or deleting incoming or
outgoing ports, but you must also click
Incoming
These are the ingress ports; an ingress port is an incoming port, that is, a port through which a data
packet enters. If you wish to allow two subscriber ports to talk to each other, you must define the
ingress port for both ports. The numbers in the top row denote the incoming port for the
corresponding port listed on the left (its outgoing port).
port. By default it forms a VLAN with all Ethernet ports. If it does not form a VLAN with a particular
port then the Switch cannot be managed from that port.
Outgoing
These are the egress ports; an egress port is an outgoing port, that is, a port through which a data
packet leaves. If you wish to allow 2 subscriber ports to talk to each other, you must define the
egress port for both ports.
with all Ethernet ports. If it does not form a VLAN with a particular port then the Switch cannot be
managed from that port.
Apply
Click
Apply
changes if it is turned off or loses power, so use the
your changes to the non-volatile memory when you are done configuring.
Cancel
Click
C a nc e l
or
.
Po rt iso la tio n
means all ports can communicate with each other, that is, there are no virtual
means that each port can only communicate with the CPU management port and
Apply
refers to the Switch management port. By default it forms a VLAN
C PU
to save your changes to the Switch's run-time memory. The Switch loses these
to begin configuring this screen afresh.
GS1350 Series User's Guide
135
(top right of screen) to display the screens as
at the bottom of the screen.
Apply
refers to the Switch management
C PU
link on the top navigation panel to save
Sa ve