Table 140 SNMP System Traps (continued)
O PT IO N
O BJEC T L ABEL
reset
zySysMgmtUncontrolledSyste
mReset
zySysMgmtControlledSystem
Reset
zySysMgmtBootImageIncons
istence
RebootEvent
timesync
zyDateTimeTrapTimeServerN
otReachable
zyDateTimeTrapTimeServerN
otReachableRecovered
intrusionlock
zyPortIntrusionLock
loopguard
zyLoopGuardLoopDetect
errdisable
zyErrdisableDetect
zyErrdisableRecovery
poe
zyPoePowerPortOverload
(For PoE models
zyPoePowerPortShortCircuit
only)
zyPoePowerPortOverSystem
Budget
zyPoePowerPortOverloadRe
covered
zyPoePowerPortShortCircuitR
ecovered
zyPoePowerPortOverSystem
BudgetRecovered
loginrecord
zyAccessControlLoginRecor
d
zyAccessControlLogoutRec
ord
zyAccessControlLoginFail
Chapter 34 Access Control
O BJEC T ID
1.3.6.1.4.1.890.1.15.3.49.2.1
1.3.6.1.4.1.890.1.15.3.49.2.2
1.3.6.1.4.1.890.1.15.3.49.2.3
1.3.6.1.4.1.890.1.5.1.1.2
1.3.6.1.4.1.890.1.15.3.82.3.1
1.3.6.1.4.1.890.1.15.3.82.3.2
1.3.6.1.4.1.890.1.15.3.61.3.2
1.3.6.1.4.1.890.1.15.3.45.2.1
1.3.6.1.4.1.890.1.15.3.24.4.1
1.3.6.1.4.1.890.1.15.3.24.4.2
1.3.6.1.4.1.890.1.15.3.59.4.1
1.3.6.1.4.1.890.1.15.3.59.4.2
1.3.6.1.4.1.890.1.15.3.59.4.3
1.3.6.1.4.1.890.1.15.3.59.4.5
1.3.6.1.4.1.890.1.15.3.59.4.6
1.3.6.1.4.1.890.1.15.3.59.4.7
1.3.6.1.4.1.890.1.15.3.9.4.1
1.3.6.1.4.1.890.1.15.3.9.4.2
1.3.6.1.4.1.890.1.15.3.9.4.3
GS1350 Series User's Guide
281
DESC RIPT IO N
This trap is sent when the Switch
automatically resets.
This trap is sent when the Switch resets by
an administrator through a management
interface.
This trap is sent when the index number of
image which is loaded when the Switch
starts up is different from what is specified
via the CLI.
This trap is sent when the Switch reboots by
an administrator through a management
interface.
This trap is sent when the Switch's date and
time is not manually entered or the
specified time server is not reachable.
This trap is sent when the Switch's real time
clock is up to date.
This trap is sent when intrusion lock occurs
on a port.
This trap is sent when loopguard shuts down
a port.
This trap is sent when an error is detected
on a port, such as a loop occurs or the rate
limit for specific control packets is
exceeded.
This trap is sent when the Switch ceases the
action taken on a port, such as shutting
down the port or discarding packets on the
port, after the specified recovery interval.
This trap is sent when the port is turned off to
supply power due to overloading.
This trap is sent when the port is turned off to
supply power due to short circuit.
This trap is sent when the port is turned off to
supply power because the requested
power exceeds the total PoE power
budget on the Switch.
This trap is sent when the port is turned on to
recover from an overloaded state.
This trap is sent when the port is turned on to
recover from a short circuit.
This trap is sent when the port is turned on to
recover from an over system budget.
This trap is sent when users log in.
This trap is sent when users log out.
This trap is sent when users fail in login.