Konica Minolta REGIUS 110 Service Manual page 265

Direct digitizer
Table of Contents

Advertisement

Sensor status detection jig
Detach Detection
Sensor Bottom
To Detach Detection Sensor
Sensor status detection jig will display the status of the sensor with the lamp by directly connecting it to
the detach detection sensor.
No.
1
Display the status of the connected detach detection sensor.
Light on: ON (transparent)
Light off: OFF (opaque)
2
It will light up on power ON.
It has a buzzer that will go on when ON is detected on both sensors.
It will be in same condition and the buzzer will sound when the sensors are not connected, so
Note
if you do want it to buzz when connecting the cables, connect the sensor cables before
connecting the USB cable.
Adjustment method
1
See
"
Removal Procedures (Page 5-11)"
remove the optical unit.
Detach Detection
Sensor Top
1
2
Function
in
"5.2.5 Removing/Installing the Optical Unit"
2
Remove the hot-cathode tube lamp.
3
Open the number 2 eraser cover.
- 1 screw (M4 x 12)
Chapter 6 Adjustment
To USB Connector
to
6-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

0902