Chapter 5 Disassembly and Assembly
Interlock Relay 2
(Brown)
MDU, etc.
(Blue)
Digital Power Supply
10
See
"
Installation Procedures (Page 5-8)"
and Insertion Unit"
Now, you have finished with the procedures to replace the condenser.
5-98
4
Remove the halogen power supply unit assembly.
•
•
First Front Side
5
Remove the bracket, then the condenser.
•
6
Install the new condenser.
•
•
7
Install the halogen power supply unit assembly
that was removed in
•
•
8
Connect the connectors removed in
fix them using the snap ties and clamps.
•
(Brown)
Interlock Switch
•
•
(Black)
Interlock
•
Relay 1, etc.
•
9
Install the electric component mount panel that
was removed in
•
in
to install the first front panel.
1 hex/Phillips-head screw (M4 x 8)
2 screws (M4 x 8)
1 screw (M3 x 6)
Bracket
1 screw (M3 x 6)
Step
4.
1 hex/Phillips-head screw (M4 x 8)
2 screws (M4 x 8)
Ties
•
Snap ties at 3 locations
Interlock relay 2
•
4 pieces (see the figure)
Standby power supply
•
CN1 (JP23: cable)
•
CN2 (JP26: cable)
Halogen power supply
•
CN1 (HCN1: cable)
•
CN2 (HCN2: cable)
•
CN3 (HCN3: cable)
Condenser
•
JJ1A (JP1: cable)
•
JP1A (JJ1: cable)
Step
2.
8 hex/Phillips-head screws (M4 x 8)
"5.2.3 Removing/Installing the Exterior Panel
Step 3
and