Chapter 5 Disassembly and Assembly
Removing the Lock Unit Assembly
Assembly Figure
5-38
Watch for orientation
5
Install the shutter unit assembly that was
removed in
Step
3.
5 tapping screws (M4 x 10)
Press it in the direction of the arrow shown in the figure
to fix it.
6
Use a 0.2 mm-spacer (film) to check the clearance
between the lock cam and the stopper block.
If the clearance is any other value than 0.2 mm, adjust
the position of the stopper block.