Konica Minolta REGIUS 110 Service Manual page 211

Direct digitizer
Table of Contents

Advertisement

Main Unit Side (Locking Pin Unit Assembly)
Work outline
Listed below are the number of people and the rough standard of work hours required for performing the
works described in this section.
Personnel
Work Hours (steps 2 to 11)
Number
1
Requirements
The works in this section can be performed using only the standard tools.
1
See
"
Removal Procedures (Page 5-6)"
Insertion Unit"
to remove the first front panel.
First Front Side
CN3
CN1
CN2
JJ10
First Front Side
Chapter 5 Disassembly and Assembly
in
"5.2.3 Removing/Installing the Exterior Panel and
2
Remove the electric component mount panel.
8 hex/Phillips-head screws (M4 x 8)
Loosen all screws.
3
Remove all connectors from the PCU.
CN1 (PCN1: cable)
CN2 (PCN2: cable)
CN3 (PCN3: cable)
4
Remove the interlock switch cable connector
(JJ10).
When removing the connector, hold a notch
on the connector without pulling a cable.
Caution
Giving a strong pull to the cable may cause
it to be broken.
5
Remove the locking pin unit assembly.
2 hex/Phillips-head screws (M4 x 8)
5-91