12
See
"
Installation Procedures (Page 5-8)"
and Insertion Unit"
to install the removed exterior panel.
Now, you have finished with the procedures to replace the justifier standard sensor.
5
Unplug the cable.
Connector (JP44)
JP44
Caution
6
Remove the justifier detection mount board 2.
1 screw (M4 x 10)
7
Remove the justifier standard sensor.
8
Install the new justifier standard sensor on the
justifier detection mount board 2.
9
See
Step 6
board 2.
1 screw (M4 x 10)
10
Connect the cable that was unplugged in
to the justifier standard sensor.
Connector (JP44)
11
See
Step 3
detection unit assembly.
1 hex/Phillips-head screw (M4 x 8)
in
"5.2.3 Removing/Installing the Exterior Panel
Chapter 5 Disassembly and Assembly
When removing the connector, hold a notch
on the connector without pulling a cable.
Giving a strong pull to the cable may cause
it to be broken.
to install the justifier detection mount
and
Step 4
to install the cassette
Step 5
5-45

Hide quick links: