Konica Minolta REGIUS 110 Service Manual page 230

Direct digitizer
Table of Contents

Advertisement

Chapter 5 Disassembly and Assembly
3
Remove the connectors in the below figure to remove the cables secured to the transformer
unit assembly with the wiring band and clamps.
When removing the connector, hold a notch on the connector without pulling a cable. Giving a
strong pull to the cable may cause it to be broken.
Caution
Removing the transformer unit assembly will remove the cables expressed with heavy lines in the figure,
which are kept attached to the unit. Remove any other cable than the above, which is attached to the unit.
CN2/PCN2
Tap Switching
Connector
JJ21
JP10
Ties
A: wiring band (cut them off)
B: snap ties (cut them off)
C: snap ties (remove them)
Transformer cables
JJ1 (JP1A: cable)
JP2 (CN2: cable)
JJ3 (JP3: cable)
JJ21 (tap switching connector)
JJ21 must be removed from the clasp.
PCU
CN2 (PCN2: cable)
Interlock switch
JJ10 (JP10: cable)
5-110
JJ3
CN2/JP25
JJ2
JP49
A
A
A
A
CN2/JP27
2 Wires at Bottom
of Interlock Relay 1
C
A
B
B
JJ1
First Front Side
Interlock relay 1
2 pieces in the lower side (left: brown,
right: black)
Digital power supply
CN2 (JP25: cable)
Digital power supply cooling fan cable
JP49 (JJ49: cable)
Analog power supply
CN2 (JP27: cable)
Halogen power supply
CN1 (HCN1: cable)
CN1/HCN1

Hide quick links: