Konica Minolta REGIUS 110 Service Manual page 49

Direct digitizer
Table of Contents

Advertisement

Initialization of the Mechanical Unit
Check if there is cassette inside the equipment and close the shutter.
Move the unit to the initial position.
Shutter:
Receiver:
Justifier guide:
Push plate unit:
Subscan unit:
Initialization sequence of the mechanical unit
Without Cassette
Subscan Unit
No
at Mechanical HP
Position?
Move Subscan
Yes
Unit to
Mechanical HP
Transporter
No
at Read Position?
Move Transporter
Yes
to Read Position
Move Transporter
to HP
Closed
Receiver home position
Justifier home position
Transporter home position
Subscan home position
Start
With Cassette
Check Cassette Detection
Sensor
Jam Evacuation
Action
No
Shutter Close?
Wait for Door
Open
Yes
Wait for Door
Shutter Open
Close
Shutter Close
Justifier at HP
Move Justifier Minutely Toward
Cassette Fixing Direction
Move Justifier
to Justifier HP
Synchronize
Receiver at
HP Position?
Move Down
Receiver Minutely
Move Receiver
End
Chapter 2 Before the Repair
No
Position?
Yes
No
Yes
to HP
2-29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

0902

Table of Contents