Chapter 6 Adjustment
10
Confirm the step in the justifier guide 2 while the cassette is fixed with the justifier guide.
If the left edge of the justifier guide 1 is between the position of the A and B of the justifier guide 2, it is
within the specification, and there is not need for adjustment of the current
Go to Step 13 if you do not need to change the Amount of Justification.
Measurement
Specified
value
6-8
Step between the justifier guide 2
and the justifier guide 1 when the
standard cassette is fixed by
justifier mechanism
2 ± 0.3 mm
11
1. Click the [Move To HP] button.
2. Change the amount of justification.
3. Click the [Position of Justification] button.
4. Confirm the step of the justifier guide 2 again.
justifier
Justifier Guide 2
Justifier Guide 1
A B
Change the justifier value if the step is not within
specification, and reconfirm.
Repeat until the step come within the specified value.
.