Download Print this page

Panasonic FP-XH Series User Manual page 98

Programmable controller
Hide thumbs Also See for FP-XH Series:

Advertisement

7.1 Table Setting Mode Control Instruction
● The target speed can be changed by rewriting the positioning parameter area with a user
program. The change is executed after it becomes a constant speed.
Precautions during programming
● If an operand is an out-of-range value, an operation error occurs.
● The stop operation has priority when the conditions of system stop, emergency stop, limit
stop and deceleration stop are satisfied.
● An operation error occurs when the system register of a specified channel is other than
"Pulse output [Table setting mode]".
● A self-diagnostic error (positioning operation error) occurs when the set value or the value of
the positioning memory (axis setting area) is abnormal.
● The JOG operation needs to be stopped for switching between the forward rotation and
reverse rotation.
● In case of changing a speed, when the target speed after the change is an out-of-range
value, the speed change is not executed and the operation continues.
Flag operations
Name
R9007
R9008
(ER)
7.1.3 [F382 ORGST] Home Return Start Instruction
Starts the home return operation according to the parameters specified in the positioning
memory (axis setting area).
Instruction format
Operand
Operand
Settings
S
Channel number to start the home return (Unsigned 16-bit integer)
7-4
Description
When the area is exceeded at the time of index modification
When the [S1] value is outside the set range
When the [S2] value is outside the set range
When the pulse output (table operation) has not been set in the system register
Setting range
0 to 5
WUME-FPXHPOSG-01